Skip to content

Download PDF by : EN 1339-AC 2006

Read Online or Download EN 1339-AC 2006 PDF

Best equipment books

's Amateur Photographer [UK] (7 May 2016) PDF

Review: novice Photographer is the world’s oldest weekly photographic journal, demonstrated in 1884. it's the revered authority for information and stories, with unique exams and investigations at the most up-to-date apparatus. The weekly contents contain interviews and columns from some of the world’s top photographers and useful strategy to encourage and enthuse the committed readership, to whom taking pictures is much greater than only a pastime.

Read e-book online IEC 61116 Ed. 1.0 b:1992, Electromechanical equipment guide PDF

Presents the longer term consumer with details permitting him to arrange the mandatory files, from the decision for tenders as much as attractiveness assessments and operation of electromechanical apparatus. Applies to installations having outputs of under five MW and generators with diameters below three m.

Extra info for EN 1339-AC 2006

Sample text

Note that Þgures 12, 13, 14, 15, 16, and 17 depict an additional local safety ground for each cabinet in addition to the equipment grounding conductor provided with the incoming power cables. When provided, this additional connection will enhance personnel safety by providing an additional low impedance path to ground. Additionally, the bus bars illustrated by Þgures 12, 13 and 17 are shown schematically for clarity. They are typically located within a master control cabinet, rather than provided as separate, external buses.

Combined with other practices of minimizing noise generation in a generating station, this system has been proven to provide protection to minimize coupling to acceptable levels. More sensitive signal and processing systems can be treated separately with the shield grounded at the source end. 38 GROUNDING IN GENERATING STATIONS IEEE Std 1050-1996 In addition to countering the above three disadvantages of conventional practice, the CDF provides an ideal system to permit trunk cabling systems. These may have substantial cost and schedule advantages.

In this type of cable, the outer conductor (shield) acts as a return path and also provides a bleed-off for stray voltages. At lower frequencies, the return current travels primarily through the ground plane rather than through the shield. Therefore, at low frequencies, the shield offers practically no magnetic shielding. 5Ð10 kHz. As the frequency increases above the cutoff frequency, the shield offers increasing attenuation. The improvement in shielding effectiveness is due to the reduction in loop area caused by current returning on the shield, rather than via the ground plane, and not by any magnetic shielding properties of the shield itself.

Download PDF sample

EN 1339-AC 2006


by George
4.1

Rated 4.43 of 5 – based on 22 votes